Link Razor PDM: Outputs, Current Budget and Wiring Design

Razor can replace suitable relay/fuse circuits with configured solid-state power distribution. Four high-power outputs and eight multi-purpose I/O channels do not mean every channel can be used as both an input and output at once.
Build a load schedule before choosing channels
Record each device’s normal and starting current, switching method and required behaviour. The manufacturer lists four high-power channels at 25 A continuous and eight ADIO channels with their own limits. Check the combined supply and operating limits; individual ratings do not simply add into an unrestricted total.
Treat multi-purpose pins as allocated resources
An ADIO used for an input is not simultaneously another independent power output. PWM and other functions also depend on the channel. Use the current manual to allocate each pin and its wiring. Do not design from a generic “twelve-output PDM” description alone.
Exact parts and the deciding checks
| Exact option | SKU | Check before choosing |
|---|---|---|
| Link Razor PDM | DX-LINK-135-1000 | Razor programmable power distribution: allocate output duties and the complete current/wire budget first. |

Link Razor PDM
Representative range photo. Razor programmable power distribution: allocate output duties and the complete current/wire budget first.
Electronic protection still needs correct wire design
Set protection and behaviour for the actual loads and wiring. The manufacturer notes specific limits on the ADIO protection arrangement, so choose wire and connectors accordingly. Keep the upstream power supply and required protection in the design; replacing a fuse box does not remove electrical engineering from the job.
Commission normal and fault behaviour
Configure and test startup, shutdown, retries, warnings and any CAN control requests deliberately. Link states Razor is not intended for safety-critical systems such as ABS or power steering. Keep those restrictions attached to the plan instead of assuming a programmable output is appropriate for every circuit in the car.
Can all eight ADIO pins be counted as inputs and eight extra outputs simultaneously?
No. Allocate each pin to its configured duty and observe channel, total-current and wiring limits. Use the current manual and keep excluded safety-critical systems out of the design.
Link Engine Management Power Distribution Modules · Explore Engine Cooling & Tuning guides
Sources and current specifications
Guide checked against the linked sources. Use the live product and selected variant for current price, availability and supplied parts; ask for confirmation where the application is unresolved.